KING PIGEON PHOTO ELECTRIC (SF-815F)WIRE SMOKE SENSOR
৳ 1,650.00
•Brand: ZYCOO
Model: PHOTO ELECTRIC (SF-815F)
Built-in remote maintenance signaling
• Drift compensation and smoothing algorithms
• Simplified sensitivity measurement
• Wide-angle, dual-color LED indication
• Loop testing via EZ Walk feature
• Built-in test switch
KING PIGEON PHOTO ELECTRIC (SF-815F)WIRE SMOKE SENSOR
Installation ease. The i3 line redefines installation ease with its plug-in design. This allows an installer to pre-wire bases (includedwith heads). The large wire entry port and in-line terminals provide ample room for neatly routing the wiring inside the base. The base accommodates a variety of back box mounting methods as well as direct mounting with drywall anchors. To complete the installation, i3 heads plug into the base with a simple Stop-Drop ’N Lock™ action.Intelligence. i3 detectors offer a number of intelligent features to simplify testing and maintenance. Drift compensation and smoothing algorithms are standard with the i3 line to minimize nuisance alarms. 2-wire i3 detectors can generate a remote LEDindicated maintenance signal when connected to the 2W-MOD2 loop test/maintenance module or a panel equipped with the i3 protocol. The SENS-RDR, a wireless device, displays the sensitivityof i3 detectors in terms of percent-per-foot obscuration.Instant inspection. The i3 series provides wide-angle red and green LED indicators for instant inspection of the detector’s condition: normal standby, out-of-sensitivity, alarm, or freeze trouble.When connected to the 2W-MOD2 loop test/maintenance module or a panel with the i3 protocol, the EZ Walk loop test feature is available on 2-wire i3 detectors. This feature verifies the initiating loop wiring by providing LED status indication at each detector.
Remove the sensor to be cleaned from the system.
2. Remove the sensor cover by pressing firmly on each of the four removal
tabs that hold the cover in place. (See Figure 4.)
3. Vacuum the screen carefully without removing it. If further cleaning is
required continue with Step 4, otherwise skip to Step 7.
4. Remove the chamber cover/screen assembly by pulling it straight out
Features:
• Plug-in detector line, mounting base included
• Large wire entry port
• In-line terminals with SEMS screws
• Mounts to octagonal and single-gang back boxes, 4-square back
boxes, or direct to ceiling
• Stop-Drop ’N Lock attachment to base
• Removable detector cover and chamber
• Built-in remote maintenance signaling
• Drift compensation and smoothing algorithms
• Simplified sensitivity measurement
• Wide-angle, dual-color LED indication
• Loop testing via EZ Walk feature
• Built-in test switch
Additional information
Operating Voltage Range: | 15 to 32 VDC |
---|---|
Operating Current @ 24 VDC: | 200 uA (one communication every 5 seconds with green LED blink on communication) |
Maximum Alarm Current | 2 mA @ 24 VDC (one communication every 5 seconds with red LED solid on) |
Maximum Current | 4.5 mA @ 24 VDC (one communication every 5 seconds with amber LED solid on) |
Operating Humidity Range: | 10% to 93% Relative Humidity, Non-condensing |
Operating Temperature Range: | 32°F to 122°F (0°C to 50°C) |
Air Velocity | 0 to 4000 ft./min. (0 to 1219.2 m/min.) |
Height: | 2.0˝ (51 mm) installed in B300-6 Base |
Diameter | 6.2˝ (156 mm) installed in B300-6 Base; 4.1˝ (104 mm) installed in B501 Base |
Weight | 3.4 oz. (95 g) |
Isolator Load Rating: * | 0.0063 |
Reviews
There are no reviews yet.